R3, R3P
REFRIGERATED SERVICE AND/OR PREP
WITH REFRIGERATED
SELF SERVICE FRONT
P/N IGFP-R3, R3P-0608
INSTALLATION & OPERATION GUIDE
/CHINO
R3, R3P
REF. SERVICE/SELF SERVICE/PREP CASE
REV. 0608
Installation
& Operation
Manual
Vista de página 0
1 2 3 4 5 6 ... 32 33

Resumo do Conteúdo

Página 1 - & Operation

R3, R3PREFRIGERATED SERVICE AND/OR PREPWITH REFRIGERATED SELF SERVICE FRONT P/N IGFP-R3, R3P-0608INSTALLATION & OPERATION GUIDE/CHINOR3, R3PREF. S

Página 2 - General Instructions

IGFP-R3, R3P-060810Boston 2000 Eco Series1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pr

Página 3 - Cut and Plan Views

Rev. 0608 11Boston 1000 SeriesNOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the exible top to ensure a proper t.NOTE:

Página 4 - GLASS BREAKAGE MAY OCCUR!

IGFP-R3, R3P-060812RefrigerationPlumbingWaste Outlet and P-TRAPThe waste outlet is located off the center of the case on one side allowing drip piping

Página 5

Rev. 0608 13Electronic Expansion Valve (Optional)A wide variety of electronic expansion valves and case controllers can be utilized. Pleas

Página 6

IGFP-R3, R3P-060814BEFORE SERVICINGALWAYS DISCONNECT ELECTRICALPOWER AT THE MAIN DISCONNECTWHEN SERVICING OR REPLACING ANYELECTRICAL COMPONENT.This in

Página 7

Rev. 0608 15Non-glare GlassWindex® or Glass Plus® are the only solutions recommended to be used to clean the non-glare glass. The damage to the glass

Página 8

IGFP-R3, R3P-060816Electrical Wiring DiagramsR3 Prep 4' W0180047 6' W0180048 8' W0180049 12' W0180051R3-P-8-REM 8

Página 9

Rev. 0608 17Wiring DiagramsDATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona A

Página 10 - Installation (Cont'd)

IGFP-R3, R3P-060818DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChi

Página 11

Rev. 0608 19DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChino, CA.

Página 12 - Plumbing

IGFP-R3, R3P-06082/CHINOA publication of HUSSMANN® Chino 13770 Ramona Avenue • Chino, California 91710(909) 628-8942 FAX(909) 590-4910 (800) 395-9229

Página 13 - Refrigeration (Cont'd)

IGFP-R3, R3P-060820DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChi

Página 14 - & OSHA Regulations

Rev. 0608 21DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChino, CA.

Página 15 - CLEANING PRECAUTIONS

IGFP-R3, R3P-060822DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChi

Página 16 - Electrical Wiring Diagrams

Rev. 0608 23DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChino, CA.

Página 17 - Wiring Diagrams

IGFP-R3, R3P-060824DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChi

Página 18 - Wiring Diagrams (Cont'd)

Rev. 0608 25DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChino, CA.

Página 19

IGFP-R3, R3P-060826DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChi

Página 20

Rev. 0608 27DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChino, CA.

Página 21

IGFP-R3, R3P-060828DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChi

Página 22

Rev. 0608 29DATE:PROJECT TITLE:DRAWING #:DRAWN BY:PRODUCTION ORDER #:DRAWING TITLE:DATE:Hussmann Corporation, Int'l.13770 Ramona AvenueChino, CA.

Página 23

Rev. 0608 3Cut and Plan ViewsR3Plan View = 1/4”48"8-2"(Variable Lengths)CASE FRONTDRAIN &ELEC.STUB UP18" X 18"8"REF.STUB

Página 24

IGFP-R3, R3P-060830Appendix A. - Temperature GuidelinesThe refrigerators should be operated according to the manufacturer’s published enginee

Página 25

Rev. 0608 311.1 The following recommendations are made for the purpose of arriving at easily taken and understood data which, coupled with other obse

Página 26

IGFP-R3, R3P-0608321.1 Cleaning of non frozen food equipment should include a weekly cleaning of the food compartment as a minimum to prevent bacteri

Página 27

The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular unit.They can be found

Página 28

IGFP-R3, R3P-06084InstallationLocationThe refrigerated merchandisers have been designed for use only in air conditioned stores where temperature

Página 29

Rev. 0608 510. Use nger to smooth silicone as thin as possible at masking tape on inside and outside of rear mullion (apply additional silicone if ne

Página 30 - Appendices

IGFP-R3, R3P-06086Installation (Cont'd)Wrapping Boards Installation InstructionsStep 1: Measure 6 inches from wrapping board end.Step 2: Measure

Página 31 - Appendices (Cont'd)

Rev. 0608 7Installation (Cont'd)Step 6: Install upper support bracketStep 7: Mount wrap board on top of bracket using a ¼” spacer to have a gap

Página 32

IGFP-R3, R3P-06088Installation (Cont'd)Bumper Installation InstructionsStep 1: Make sure the aluminum channel and end caps are installed.Ste

Página 33 - Service Record

Rev. 0608 9Boston Series 2000NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the exible top to ensure a proper t.NOTE: